We use cookies. For more information go to privacy policity
RU
+7 (342) 279-75-55
+7 (908) 270-75-55

Heating modules HT

Hopper heating module Thermon HT

Application of Thermon heating module HT

heating-bunker-panelsThe HT hopper heating module is a rugged, self-contained high performance heater designed for reliable operation on surfaces prone to vibration. Designed to provide heat outputs up to 3 watts per square inch (4,650 watts per square meter) depending on the application, the HT module distributes heat evenly over the entire panel surface. To ensure optimal performance, each system is engineered by Thermon based on the heating requirements of the application.

A parallel circuit design, based on a stamped high temperature INCONEL® heating element, provides the HT heating module with multiple flow paths for electrical current to pass. This design eliminates the burnout potential common with series wire-based designs. Protection of the heating element from vibration is achieved with a cushion layer of insulation that also directs the flow of heat from the module to the surface being heated.

The rugged construction of the module includes a tough 20- gauge aluminized steel that provides mechanical protection during handling, installation and operation. Weld splatter, rust or oil will not affect the integrity or performance of the heater. The low profile design of the panel permits rapid, trouble free installation with the template and mounting kit available from Thermon.

HT hopper heating modules are approved for use in ordinary (nonclassified) and hazardous (classified) areas.

Construction of heating module HT

heating-bunkersFluoropolymer insulated high temperature 16 AWG lead wires (with stress relief at connection);

Parallel circuit high temperature alloy heating element;

Temperature-rated insulation (directs energy towards surface to be heated);

20-Gauge aluminized steel protective enclosure;

20-Gauge aluminized steel protective cover with reinforcing attachment channel.

Ratings of module Thermon HT

  • Maximum watt density: 3 w/in2 (4,650 w/m2)
  • Supply voltages: 120-600 Vac
  • Max. maintenance temperature: 800°F (427°C)
  • Max. continuous exposure temperature
    Power-off: 1,000°F (538°C)
  • Minimum installation temperature: - 40°F (- 40°C)

Available HT module sizes

Catalog number base module Module dimensions in (cm) Stud spacing in (cm)
612 15x40 36
624 15x70 65
636 15x99 94
648 15x129 123
212 30x40 36
224 30x70 65
236 30x99 94
248 30x129 123